|
31. TSD202A | Fast Response Thermistor, TP | BIOPAC - Research
|
|
probe appropriate for use in locations where temperature changes rapidly, as with the temperature changes of inspired/expired breath. TAPE1 is recommended to secure the TSD202A in place.
Response time: 0.6 sec
Dimensions: 1.7mm (dia) x 5mm (long)
Replacement sensor available: RX202A
See SS6 for the Telemetry System equivalent.
Topics
Cleaning guidelines Transducer calibration using two values
|
|
|
|
32. TSD202B | Surface Probe Thermistor, TP | BIOPAC - Research
|
|
on a variety of body locations. The stainless steel banjo design insures rapid and uniform recording of skin surface temperatures. Use TAPE1 to secure the transducer to the skin surface.
Response time: 1.1 sec
Size: 9.8mm (dia) x 3.3mm (high)
Topics
Cleaning guidelines Transducer calibration using two values
|
|
|
|
33. SS7 | Temperature, Skin Surface, SS | BIOPAC - Research
|
|
on a variety of body locations. The stainless steel banjo design insures rapid and uniform recording of skin surface temperatures.
Use TAPE1 to secure the transducer to the skin surface.
See TSD202D or the MP150 or MP100 System equivalent.
Topics
Amplifier filter settings Cleaning guidelines ECG Analysis Extracting heart rate from a noisy ECG signal Goniometer resolution NIBP100A and pulse plethysmography
|
|
|
|
34. TEL100C-RF | Wireless Remote Monitoring Sys | BIOPAC - Research
|
|
from up to four distinct locations. Each channel incorporates a switchable, non-distorting 50/60 Hz interference filte. Gain and bandwidth can be adjusted independently for each channel.
The TEL100C-RF will work with your current MP System and any other standard 100-series amplifiers. Use with BIOPAC SS Series Simple Sensor transducers and electrodes.
See Support > Application Note #126 for connection details, operational guidelines, and specification comparison with the TEL100C Remote Monitoring System in the Resource Tab.
BIOPAC does not recommend converting the wireless TEL100C-RF to a tethered system; TEL100C-RF
|
|
|
|
35. TSD200 | Photo Plethysmograph Trans TP | BIOPAC - Research
|
|
can be taped to other body locations. The TSD200 comes with a shielded 3-meter cable.
See also
TSD200B—PPG with adhesive collars for easy attachment to ear or other body parts
Telemetry System equivalent—SS4A
BIOPAC MRI Guidelines
Topics
Cleaning guidelines Deep breath and PPG signal flattening NIBP100A and pulse plethysmography PPG setup and calibration
|
|
|
|
36. SS7 | Temperature, Skin Surface, SS | BIOPAC - Research
|
|
on a variety of body locations. The stainless steel banjo design insures rapid and uniform recording of skin surface temperatures.
Use TAPE1 to secure the transducer to the skin surface.
See TSD202D or the MP150 or MP100 System equivalent.
You might also be interested in the following items:
Item
Description
TEL100C 4-chan Remote Monitoring Sys
|
|
|
|
37. TEL100C-RF | Wireless Remote Monitoring Sys | BIOPAC - Research
|
|
from up to four distinct locations. Each channel incorporates a switchable, non-distorting 50/60 Hz interference filte. Gain and bandwidth can be adjusted independently for each channel.
The TEL100C-RF will work with your current MP System and any other standard 100-series amplifiers. Use with BIOPAC SS Series Simple Sensor transducers and electrodes.
See Support > Application Note #126 for connection details, operational guidelines, and specification comparison with the TEL100C Remote Monitoring System in the Resource Tab.
BIOPAC does not recommend converting the wireless TEL100C-RF to a tethered system; TEL100C-RF
|
|
|
|
38. TSD110 | Respiration Pad Transducer | BIOPAC - Research
|
|
works on a number of body locations (affix with TAPE1). The multipurpose assembly can be used to:
Measure pulse when placed on a major pulse point.
Noninvasively measure respiration—from a small mouse to a human.
Measure small pressing forces (like pinching fingers together) for Parkinson’s evaluations.
Measure human facial expressions (smiling, frowning, etc.)
Measure spacing and pressure between teeth coming together.
Measure startle blink response.
Respiration
Animals : For high-quality respiration signals,
|
|
|
|
39. TSD110-MRI | Pressure Pad / Respiration Trans. for MRI | BIOPAC - Research
|
|
works on a number of body locations (affix with TAPE1). The multipurpose assembly can be used to:
Measure pulse when placed on a major pulse point.
Noninvasively measure respiration—from a small mouse to a human.
Measure small pressing forces (like pinching fingers together) for Parkinson’s evaluations.
Measure human facial expressions (smiling, frowning, etc.)
Measure spacing and pressure between teeth coming together.
Measure startle blink response.
Respiration
|
|
|
|
40. SS7 | Temperature, Skin Surface, SS | BIOPAC - Research
|
|
on a variety of body locations. The stainless steel banjo design insures rapid and uniform recording of skin surface temperatures.
Use TAPE1 to secure the transducer to the skin surface.
See TSD202D or the MP150 or MP100 System equivalent.
Response time:
1.1 sec
Nominal resistance:
2252 Ohm @ 25°C
Maximum operating temperature:
60°C (when used with SKT100C)
Accuracy and interchangeability:
0.2°C
Compatibility:
YSI @ series 400
|
|
|
Result page:
Previous
Next
|